Mnova Logo

The Mnova Tablet app in its full version contains all the basic functionality described in the free version (we recommend you to read the tutorial to get you started in the basic tablet app options and visualization tools) plus the main NMR processing parameters and analysis tools, as well as some extra visualization options.

For basic functionality (i.e. referencing, normalization) and visualization of the spectra you can have a look at the free version functionality tutorial.

The crosshair tool is enabled with the main analysis parameters: peak picking, integration and multiplets analysis and also with the zoom in tool.

Processing tools

The main processing tools available are:

– Apodization

– Zero filling and linear prediction

– Phase correction

– Baseline correction

 

APODIZATION:

Used when the signal decays rapidly to zero producing an abrupt truncation of the FID.

 

Screenshot_2015-05-08-20-05-59b

 

 

 ZERO FILLING and LINEAR PREDICTION:

Zero filling is used to set the size of the Fourier Transform and Linear Prediction is a mathematical procedure where a missing part of a FID can be constructed in order to increase the digital resolution of the spectrum.

You can edit the zero filling and linear prediction window functions as per in your Mnova desktop version.

 

Screenshot_2015-05-08-20-06-36b

 

PHASE CORRECTION:

Phase errors can be easily rectified in software by applying a lineal combination of the real and imaginary components of the spectrum in order to obtain pure phase lineshapes.

You can use the following interface to adjust any phase shift.

 

Screenshot_2015-05-08-20-07-28b

 

BASELINE CORRECTION:

Modern spectrometer hardware uses oversampling and digital signal processing to improve the baseline, but some undesirable broad signals arise from real sources. Just click on the baseline icon as shown below and this will execute a ‘Full Auto’ baseline correction for you.

 

Screenshot_2015-05-08-20-08-15B

 

Analysis tools

PEAK PICKING, INTEGRATION and MULTIPLET ANALYSIS:

Peak picking and integration can be perform automatically (tapping on the peak picking and integration icons on the left toolbar). Multiplet analysis has to be performed manually.

Screenshot_2015-05-08-20-09-06b

 

A multifunction cross-hair allows you to manually add peaks, integrals and multiplets to the spectrum. Just tap the icon of the desired functionality in the center of the cross-hair and drag it across the spectrum to define a region as seen below:

 

Screenshot_2015-05-08-20-09-47d

 

 

Screenshot_2015-06-15-19-10-02

Visualization tools

 

In addition to all the visualization tools available on the free version, the full version allows you two more ways to zoom in the spectra.

One way is to use the crosshair tool dragging it across the spectra as per the analysis tools. Another option, possibly the recommended one, is to select the zoom in icon on the tool bar and drag across the spectra.

 

Screenshot_2015-05-11-17-00-05b

 

Other tools

Deleting multiplets, integrals, etc. You just need to select the delete icon on the bottom left corner and then select what you want to delete on the spectra. Remember to unselect this tool to come out the deleting mode.

 

Screenshot_2015-05-11-17-07-56b

 

In this case a multiplet at 10.4ppm has been deleted by tapping on the multiplet box:

 

Screenshot_2015-05-11-17-08-23b

 

Some extra hints about 2D spectra

PROCESSING OPTIONS:

Both dimensions f1 and f2 are enabled for 2D processing.

 

Screenshot_2015-05-13-13-29-02B

 

 LOADING 1D TRACES ON A 2D SPECTRA:

Select the traces icon highlighted below, and then just pick a suitable display mode. Traces will be automatically displayed once you select the view option.

 

Screenshot_2015-05-13-13-30-11c

 

ZOOMING IN:

For 2D spectra, the only difference is that you have to drag across (diagonally) the desired area to zoom in.

 

Screenshot_2015-05-13-13-38-08

 